Rugged Over-Voltage Protection OVP2

OVP2

Configure Your Product:
OVP2

This product requires configuration. To select the different options for this product continue to the Configuration Tool. Need help selecting the right options for your application? Contact Us.
Configuration Tool
Configure Your Product

Product Description

Unlike other “arrester” type over-voltage products, the OVP2 uses solid-state switching components to conduct at very low voltages, providing the most reliable over-voltage protection available to the industry. The OVP2 is rated for AC fault current, and lightning, ensuring peak performance for the product’s long life vastly outperforming other protection products such as spark gap arresters and surge diverters.

The OVP2 is UL and C-UL listed for use in Division 2 or ordinary locations, as well as CE marked as meeting the ATEX requirements for Zone 2.

Note: the OVP2 is not suitable for applications where steady-state induced AC voltage exists between the connection points.

Certifications:
UL Canada & United States
C E
ATEX
Ex
IEC
IECEx
UKEx
AC Fault Current (Amperes-RMS) 50/60Hz
1.2kA at 30 cycles
2.0kA at 30 cycles
3.7kA at 30 cycles
5.0kA at 30 cycles

Review the Technical Literature for full fault current tables.

Lightning Impulse Current
100kA crest (8 x 20 µs waveform)

Class N 50kA crest* (10 x 350 µs waveform)
*optional unless required by international standards

Class N (ISG class N withstand lightning current per IEC 62561-3:2017)

Environmental Rating
IP68 - Submersible (to 2m depth)
Threshold Voltage
-2/+2V (standard)
-3/+1V (optional)
Hazardous (Classified) Areas
ANSI/ISA: Class I, Division 2, Groups A, B, C, D
ATEX: Zone 2, Group IIC
IECEx: Zone 2, Group IIC
UKEx: Zone 2, Group IIC

The OVP2 has been tested by Nationally Recognized Testing Laboratories (NRTLs) for compliance to independent standards in its operation, ratings, and construction.  This includes compliance to standards for:

Class I, Div. 2, Groups A, B, C, D and Zone 2, Group IIC

Class & Division System: UL (United States) and C-UL (Canada)

  • Effective Ground Fault Current Path per:
    • NFPA 70 (US National Electric Code – NEC): Article 250.4(A)(5)
    • CSA C22.1 (Canadian Electric Code, Part I): 10-100 & 10-500
  • Isolation of Objectionable DC Ground Currents per:
    • NFPA 70: Article 250.6(E)
    • CSA C22.1: 10-100 & 10-500
  • Hazardous Location Use: Class 1, Division 2, Groups A, B,C,D by UL & C-UL per:
    • UL 121201, 9th and CSA C22.2 No.213-17
  • Safety Requirements for Electrical Equipment per:
    • UL 61010-1, 3rd & CSA C22.2 No. 61010-1
    • Overvoltage Protection from Impulse (Lightning) Current: 100kA (8 x 20µs)
    • Enclosure Rating: IP68 (Submersible to 2 meters depth)
    • Temperature Range: -45°C to +65°C  (-49°F to +149°F)

Zone System: ATEX / IECEx / UKEx (Europe / International / UK). ATEX per directive 2014/34/EU (Equipment for use in Potentially Explosive Atmospheres): 

  • Zone 2, Group IIC, Increased Safety “ec”
  • EN IEC 60079-0: 2018
  • EN IEC 60079-7: 2015+A1:2018
  • IEC 60079-0: 2017
  • IEC 60079-7: 2017
  • Overvoltage Protection from Impulse (Lightning) Current: 100kA (8 x 20µs)
  • Temperature Range: -45°C to +65°C
  • Enclosure Rating: IP68