• Dairyland Electrical Industries
  • Home
  • Products
  • Applications
  • Industries
  • Catalog
  • Contact

PCRH • Polarization Cell Replacement for Hazardous Locations

Overview

Product Matrix

DEI offers two versions of the PCR for addressing hazardous (classified) locations: the standard PCR for Class I, Div 2 and Zone 2 areas, and the PCRH for Class I, Div 1 & 2 areas. Having been fully tested and listed by Underwriter's Laboratory (UL) to the US and Canadian standards, the device carries the UL mark and C-UL (Canada) mark. No other known company offers decouplers with third-party listings for hazardous locations.

Features and Characteristics

• UL, C-UL listed explosion-proof design: unique to the industry
• Uses the same solid-state internal construction as our industry standard PCR
• Listed for use in Division 1 & 2 areas, Groups C, D
• Listed as an "effective grounding path" per the NEC and CSA grounding standards
• Offered with optional customized lead kits

Ratings

For full product information see PCRH Documentation

Threshold Voltage
-3/+1V (standard)
-2/+2V (optional)
Other voltages optional

AC Steady-State Current (amperes - rms) 50/60Hz

45A (standard)

Lightning Surge Current
100kA crest (8 x 20 µs waveform)

AC Fault Current (amperes-rms) 60 Hz
Model 1 cycle 3 cycles 10 cycles 30 cycles
PCRH-3.7KA-CD 6,500 5,000 4,200 3,700
PCRH-5KA-CD 8,800 6,800 5,700 5,000
PCRH-10KA-CD 20,000 15,000 12,000 10,000
PCRH-15KA-CD 35,000 27,000 21,000 15,000
AC Fault Current (amperes-rms) 60 Hz
Model 1 cycle 3 cycles 10 cycles 30 cycles
PCRH-3.5KA-CD 6,100 4,700 3,900 3,500
PCRH-5KA-CD 8,800 6,800 5,700 5,000
PCRH-9KA-CD 19,000 14,000 11,000 9,000
PCRH-14KA-CD 33,000 25,000 19,000 14,000

Environmental rating:
NEMA 4

Hazardous (classified) areas:
Per NEC, CSA: Class I, Division 1 & 2, Groups C, D

Third-party listings and approvals:

Underwriter's Laboratories (UL)
Underwriter's Laboratories - Canada (C-UL)

See full Certifications/Listings for the PCRH

Certifications

Documentation

Literature:

Support Documents:

Certifications & Listings
Competitive Comparisons

Application Assistance:


Certifications

Competitive Comparisons

Comparison of Dairyland model PCRH to other solid-state devices

Following on the success of the model PCR, the Dairyland model PCRH offered fully certified products for Class I, Division 1 hazardous locations. There are no equivalents to the model PCRH, however it is common for others to place a protection product inside of a commercially available explosion-proof box and erroneously consider the entire package to be considered "explosion-proof." Altering a certified enclosure nullifies the listing or certification unless the entire package is again tested and recertified. Dairyland has taken the route of full testing and certification for the model PCRH, as it is used in explosive atmospheres. The device was successfully tested and certified.

The PCRH has extensive certification. In fact, no other products of this type on the market have any known certification to any standards whatsoever. Consider the following PCRH certifications:

• UL listed as an "effective grounding path" per the US National Electrical Code (NEC)
• UL listed for blocking cathodic protection current per the US NEC
• UL listed as meeting the lightning surge current standards
• UL listed for Class I, Division 1 & 2 hazardous locations
• UL listed NEMA 4 environmental rating
• C-UL listed as an "effective grounding path" per the Canadian Electrical Code
• C-UL listed for Class I, Division 1 & 2 hazardous locations
 

Other features include:

• Unique, patented construction that assures maintenance-free operation
• Assured fail-safe design, independently tested
• Proprietary manufacturing methods that assure corrosion resistance, high AC fault capability, and low leakage current

For more information on PCRH certification, see the full data sheet.

Certifications and Listings

The PCRH has been tested by a Nationally Recognized Testing Laboratory (NRTL) for compliance to independent standards in its operation, ratings, and construction. This includes compliance to standards for:

Safety Grounding
UL (United States) and C-UL (Canada) listing for:
• Providing an "effective ground-fault current path" as defined in 2002 NFPA 70 (US National Electrical Code - NEC), Article 250.2, and required in 250.4 (A)(5)
• Similarly, it meets the same per Canadian Standards Association CSA C22.2 No. 0.4-M1982 (reaffirmed 1999), using Canadian Electrical Code Part I, section 10-500, 10-806 as a guide.
• Providing over-voltage protection in accordance with the applicable requirements of ANSI C62.11

Listing assures compliance to the above standards by DEI devices in providing electrical over-voltage protection and safety grounding.

Blocking Cathodic Protection Current
• Providing DC isolation of objectionable DC ground currents from cathodic protection systems as defined in NFPA 70, Article 250.6(E)

HAZARDOUS LOCATION USE
The PCRH has been listed for use in Class I, Divisions 1 & 2, Groups C, D hazardous locations by UL and C-UL, according to:
• U.S. National Electrical Code section 500-505
• UL 1203: "Explosion-proof and Dust-Ignition Proof Electrical Equipment for Hazardous (Classified) Locations"
• CSA C22.2 No.30-M1986: "Explosion-Proof Enclosures for Use in Class I Hazardous Locations"

Additional Media

PCRH Install
PCRH Install
PCRH Install

Accessories

PMK - Pipe Mounting Kit

Any PCR model can mount to this free-standing kit, supplied with a stainless steel backplate, 2"diameter steel pipe, anchor base and hardware.

AP - Adaptor Plate Kit

Adaptor Plates can be furnished to simplify making connection to a flange using one of the flange bolts. Kit supplied with either crimped or bolted wire terminals.

Pedestal

Use this 36" padlockable fiberglass pedestal with any model PCR to enclose the device and all cable connections. Used in applications where cable lead connections come from below ground level, typically AC mitigation schemes.

Pedestal
ACL-18 PCRH Leads

Consists of insulated 2/0 AWG stranded copper leads for connecting the PCRH terminals to the structure.